Physical Characteristics

Raid Controller AMCC440SP RAID engine
Host Interface Dual-ported active-active 4Gb Fibre Channel
Disk Interface SAS/ SATA II drive support
Row capacity 24 TB SATA II
Maximum cache 4GB
Internal disk drive options 146GB SAS (15,000 RPM)
300GB SAS (15,000 RPM)
450GB SAS (15,000 RPM)
600GB SAS (15,000 RPM)
500GB SATA II (7,200 RPM)
1TB SATA II (7,200 RPM)
2TB SATA II (7,200 RPM)


RAID Configurations

RAID Levels 0, 1, 1+0, 3, 5, 6
Maximum LUNs Up to 256 LUNs
Maximum concurrent hosts Up to 32 concurrent hosts
Max. local/ Global hot spares Up to 16 drives
Cache battery backup Up to 72 hours


Availability, Reliability, Serviceability

Non-disruptive firmware upgrades
Non-disruptive component replacement (Major FRU)
Non-disruptive hot-swap RAID controllers with battery-backed mirrored
Non-disruptive hot-swap disk drives per RAID and per expansion tray
Disk Drive failure detection and rebuild
Dual hot-swap, redundant, load-sharing power supply
Hot-swap and redundant cooling fans
Local and global hot sparing


Supported Host Platforms

Microsoft Windows 2000
Microsoft Windows Server 2003
Linux


Dimensions and Weight

Height Width Depth Weight
3.44 in. (87.4mm) 17.67 in. (445mm) 22.86 in. (580mm) 55.05 lb. (24.97kg)
2U 19" with 12 hard drives


Operation Environment

Temperature 0°C to 35°C (32°F to 95°F)
Humidity (non-condensing) 5% to 95%
Altitude -50 to 10,000 feet
Shock 31G@ 2.6ms, half-sine wave pulse
Vibration 0.25G@ 3Hz to 200Hz


Electromagnetic Emissions Standards

Microsoft Windows 2000
Microsoft Windows Server 2003
Linux


Electrical Requirements

Input Voltage 100 - 240 VAC
Input Frequency 50 - 60 Hz
Input Current 100 - 240 VAC@9
Output Power 500 W


Safety Standards

UL/ CUL: for U.S. with Canada/ UL60950-1
TUV: for Germany/ EN60950-1
CB (by TUV): IEC60950-1
BSMI: Taiwan/ CNS14336
CCC: for China
EU RoHS & China RoHS Compliant


Software Supports

Management Software FusionStor Qtrace Management System