Host Interface | Two SAS 3Gb wide ports |
Disk Interface | SAS / SATA II drive support |
Internal disk drive options | 146GB SAS (15,000 RPM) 300GB SAS (15,000 RPM) 450GB SAS (15,000 RPM) 600GB SAS (15,000 RPM) 500GB SATA II (7,200 RPM) 1TB SATA II (7,200 RPM) 2TB SATA II (7,200 RPM) |
No single point failure of redundant controllers |
Non-disruptive component replacement (Major FRU) |
Non-disruptive hot-swap controllers |
Non-disruptive hot-swap disk drives |
Dual hot-swap, redundant, load-sharing power supply |
Hot-swap and redundant cooling fans |
Support inband(SAS) and out-of-band(rs232) firmware upgrade |
Microsoft Windows 2000 |
Microsoft Windows Server 2003 |
Linux |
Solaris |
Height | Width | Depth | Weight |
6.9 in. (175mm) | 17.67 in. (445mm) | 22 in. (557mm) | 91.63 lb. (41.56kg) |
Temperature | 0°C to 35°C (32°F to 95°F) |
Humidity (non-condensing) | 20% to 95% |
Altitude | -50 to 10,000 feet |
Shock | 31G@ 2.6ms, half-sine wave pulse |
Vibration | 0.25G@ 3Hz to 200Hz |
FCC-Class A |
CE-Specifically requirements in effect July 1, 2001 |
VCCI - for Japan |
CCC - for China |
BSMI - for Taiwan/ CNS/ 3438 |
C-TICK - for Australia and New Zealand |
Input Voltage | 88 - 264 VAC |
Input Frequency | 47 – 63 Hz |
Output Power | 500 W |
UL/CUL: for U.S. with Canada / UL60950-1 |
TUV: for Germany / EN60950-1 |
CB (by TUV): IEC60950-1 |
BSMI: Taiwan/ CNS14336 |
CCC: for China |
Management | SES Management System |
LSI MegaRaid | |
Adaptec Storage Manager | |
3ware 3DM | |
FusionStor SES Management System |